Mjk-automation Shuttle Ultrasonic Level Transmitter and Sensor Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Fontes de alimentação Mjk-automation Shuttle Ultrasonic Level Transmitter and Sensor. MJK Automation Shuttle Ultrasonic Level Transmitter and Sensor User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 70
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
1
SW 838023
GB Shuttle Manual 100316
MJK Automation A/S
Byageren 7
DK-2850 Nærum
Denmark
Tel.: +45 45 56 06 56
Fax: +45 45 56 06 46
www.mjk.com
Ultrasonic Level Transmitter
and Sensor
User Manual
New setup procedure.
See page 14 for choosing correct
sensor type at initial setup.
All MJK’s newest ultrasonic
sensors covered and described
in this manual
New
Vista de página 0
1 2 3 4 5 6 ... 69 70

Resumo do Conteúdo

Página 1 - User Manual

1SW 838023GB Shuttle Manual 100316MJK Automation A/SByageren 7DK-2850 NærumDenmarkTel.: +45 45 56 06 56Fax: +45 45 56 06 [email protected]

Página 2 - IMPORTANT

10GB Shuttle Manual 100316SW 838023 MountingUltrasonic sensorThe ultrasonic sensor is delivered as stand-ard with 12 metres of cable. The ultrasonic

Página 3 - Table of Contents

11SW 838023GB Shuttle Manual 100316 Display and keyboardDisplay and keyboardGeneralThe keyboard is used only for the initial programming of the Shutt

Página 4 - SW 838023

12GB Shuttle Manual 100316SW 838023 Display and keyboardDisplayed during normal serviceNumerical read-out of the actual level.Bar graph for indicatio

Página 5 - Introduction

13SW 838023GB Shuttle Manual 100316 Display and keyboardThe keyboardFrom the Shuttle® keyboard the keys marked A - F (➀) gives access to 21 menus div

Página 6

14GB Shuttle Manual 100316SW 838023 Display and keyboardGet startedApplying powerWhen Shuttle® is connected to power for the first time, the fol-lowin

Página 7

15SW 838023GB Shuttle Manual 100316 Display and keyboard- the well is empty…- the well is not empty…The distance from the sen-sor to the zero point o

Página 8

16GB Shuttle Manual 100316SW 838023 Display and keyboardBasic settingsThe automatic setting of the zero point and the mA output made by Shuttle® duri

Página 9

17SW 838023GB Shuttle Manual 100316 Display and keyboardUnits of measurementIf the measuring unit is changed, all other values in menus and settings

Página 10 - Mounting

18GB Shuttle Manual 100316SW 838023 Display and keyboardSensor to zero point distanceThe level read-out (zero point) can be adjusted as required. Thi

Página 11 - Display and keyboard

19SW 838023GB Shuttle Manual 100316 Display and keyboardLevel read-outThe well is not emptyWith this function the level read-out can be increased or

Página 12

2GB Shuttle Manual 100316SW 838023 Ultrasonic Level Transmitter and SensorCE Certificate of ConformityThis product complies with the requirements conc

Página 13

20GB Shuttle Manual 100316SW 838023 Display and keyboardmA outputWhen Shuttle® is connected to the power supply for the first time, the mA-output is a

Página 14

21SW 838023GB Shuttle Manual 100316 Display and keyboardRelay outputsSelection of relays 1 and 2Three functions are available:- pump control with al

Página 15

22GB Shuttle Manual 100316SW 838023 Display and keyboardPump control with relays 1 and 2With these start and stop levels Shuttle® is now configured fo

Página 16

23SW 838023GB Shuttle Manual 100316 Display and keyboardLevel control with relay 1Shuttle® reverts to normal read-out.0,50 m(deactivate)1,00 m(activa

Página 17

24GB Shuttle Manual 100316SW 838023 Display and keyboardSystem alarm on relay 1Shuttle® reverts to normal read-out.Select the time delay.Select relay

Página 18

25SW 838023GB Shuttle Manual 100316 Display and keyboardSelection of relay function for relay 2Two functions are available: - level control- system

Página 19

26GB Shuttle Manual 100316SW 838023 Display and keyboardLevel control with relay 2Shuttle® reverts to normal read-out.0,50 m1,00 mSelect relay mode.

Página 20

27SW 838023GB Shuttle Manual 100316 Display and keyboardShuttle® reverts to normal read-out.Select the desired time delay.Select relay mode. ('n

Página 21

28GB Shuttle Manual 100316SW 838023 Display and keyboardStart of the learning functionFirst time activationWith this function Shuttle® learns if ther

Página 22

29SW 838023GB Shuttle Manual 100316 Display and keyboardActivating the learning functionActivation / deactivationThis function activates or deactivat

Página 23

3SW 838023GB Shuttle Manual 100316 Ultrasonic Level Transmitter and SensorTable of ContentsIntroduction ...5About this

Página 24

30GB Shuttle Manual 100316SW 838023 User and factory settingsSettingsUser settingsbArArEAPS.ErrLEUser and factory settingsFactory settingsLearning fu

Página 25

31SW 838023GB Shuttle Manual 100316 User and factory settingsPossible settingsLearning function: On / OffMeasuring unit: m / in / ft / mm / cmSen

Página 26

32GB Shuttle Manual 100316SW 838023 Fault findingFault findingGeneralAlmost all system errors are due to the echo from the ultrasonic sensor being eith

Página 27

33SW 838023GB Shuttle Manual 100316 Fault findingPower failureIf one of the relay outputs is set to NC (normally closed), an external alarm is im-medi

Página 28

34GB Shuttle Manual 100316SW 838023 Fault findingShuttle® indicates system error constantlyShuttle®Setting Is the setting of the active measuring ran

Página 29

35SW 838023GB Shuttle Manual 100316 Ex InstructionsQuick Installation Guide - FM-approved MJK Ultrasonic SensorsMJK North America, Inc.37 Sherwood Te

Página 30 - User and factory settings

36GB Shuttle Manual 100316SW 838023 Ex InstructionsDenmark [email protected]+45 45 56 06 56The [email protected]+31 251 672171No

Página 31

37SW 838023GB Shuttle Manual 100316 AppendixA Technical specificationsDimensionsShuttle® Level TransmitterShuttle® Ultrasonic SensorUniversal bracket

Página 32 - Fault finding

38GB Shuttle Manual 100316SW 838023 Appendix9090606030300-40-30-20-10dBStandard Range VersionShuttle® Ultrasonic SensorsShuttle® Ultrasonic Sensor Ty

Página 33

39SW 838023GB Shuttle Manual 100316 Appendix9090606030300-40-30-20-10dBStandard Range Version/FM ApprovedShuttle® Ultrasonic Sensor Types 200640 / 20

Página 34

4GB Shuttle Manual 100316SW 838023 Ultrasonic Level Transmitter and SensorA Technical specifications ...37Dimensions ...

Página 35 - Ex Instructions

40GB Shuttle Manual 100316SW 838023 Appendix9090606030300-40-30-20-10dBExtended Range VersionShuttle® Ultrasonic Sensor Types 200630 / 200631Measurin

Página 36

41SW 838023GB Shuttle Manual 100316 AppendixChemical Resistant VersionShuttle® Ultrasonic Sensor Type 200660Measuring range 10 m (liquids), 5 m (soli

Página 37 - Appendix

42GB Shuttle Manual 100316SW 838023 AppendixB Changing supply voltage1: Remove the lid, detach the wires from the terminal blocks and remove the fo

Página 38

43SW 838023GB Shuttle Manual 100316 AppendixC Sensor mounting considerationsGeneralThe ultrasonic sensor is characterized by a very narrow spread of

Página 39

44GB Shuttle Manual 100316SW 838023 AppendixMeasurements Along a wall / other surfaceThe values in table 1 assume the ultrasonic signal is sent alon

Página 40

45SW 838023GB Shuttle Manual 100316 AppendixD Service menuShuttle® has a service menu that gives ac-cess to settings that normally are not altered b

Página 41

46GB Shuttle Manual 100316SW 838023 AppendixE Special menusUnder certain circumstances it may be nec-essary to make adjustments and to make readings

Página 42

47SW 838023GB Shuttle Manual 100316 AppendixBar graph read-outThis function is used to select whether the bar graph should follow the analog output o

Página 43

48GB Shuttle Manual 100316SW 838023 AppendixActive measuring rangeShuttle®'s measuring range is normally set automatically to a distance corresp

Página 44

49SW 838023GB Shuttle Manual 100316 AppendixShuttle® reverts to normal read-out.Response timeWhen the level changes, the display read-out will change

Página 45

5SW 838023GB Shuttle Manual 100316 IntroductionIntroductionThank you for choosing a Shuttle® Ultra-sonic Level Transmitter.We have done everything po

Página 46

50GB Shuttle Manual 100316SW 838023 AppendixMeasuring method (application)Shuttle®'s high accuracy is partly obtained by controlling the strengt

Página 47

51SW 838023GB Shuttle Manual 100316 AppendixShuttle® reverts to normal read-out.mA output signal during system errorThis function determines how the

Página 48

52GB Shuttle Manual 100316SW 838023 AppendixCalibration of the level measurementIf the distance of the ultrasonic sensor above the surface is known,

Página 49

53SW 838023GB Shuttle Manual 100316 AppendixOffset level readoutShuttle® can display the levels with reference to a selectable offset level.This mean

Página 50

54GB Shuttle Manual 100316SW 838023 AppendixIndication of echo qualityThis menu is used to indicate the strength of the received ultrasonic echo.If t

Página 51

55SW 838023GB Shuttle Manual 100316 AppendixIndication of signal amplificationThis menu is used to display the amplification level of the received ultr

Página 52

56GB Shuttle Manual 100316SW 838023 AppendixIndication of time period without echoThis menu is used to display the longest time period during which S

Página 53

57SW 838023GB Shuttle Manual 100316 AppendixSelect factory settingsAll settings - except calibration of the level measurement - made after initial st

Página 54

58GB Shuttle Manual 100316SW 838023 AppendixAccess codeTo gain acces to the remaining menus, an access code is required.…and confirm with 'ENTER&

Página 55

59SW 838023GB Shuttle Manual 100316 AppendixReadout of version numbersEnter the access code (see page 58) and press'A':This menu is used to

Página 56

6GB Shuttle Manual 100316SW 838023 IntroductionAn identical marking can be found on the right hand side of the level transmitter cabinet:Product iden

Página 57

60GB Shuttle Manual 100316SW 838023 AppendixUse the arrow keys to select:Confirm the new setting:Shuttle® is ready for a new selection of a password p

Página 58

61SW 838023GB Shuttle Manual 100316 AppendixFixed mA signalEnter the access code (see page 58) and press 'C'.This menu is used to make Shut

Página 59

62GB Shuttle Manual 100316SW 838023 AppendixUse the arrow keys to select a new value:Confirm the new setting:The actual setting is shown immediately:

Página 60

63SW 838023GB Shuttle Manual 100316 AppendixSystem alarm delayEnter the access code (see page 58) and press 'E':Shuttle® will give a system

Página 61

64GB Shuttle Manual 100316SW 838023 AppendixAveraging the level measurementEnter the access code (see page 58) and press 'F':When measuring

Página 62

65SW 838023GB Shuttle Manual 100316 AppendixUse the arrow keys to select a new value: (5 dB increments.) Confirm the new setting:The actual setting is

Página 63

66GB Shuttle Manual 100316SW 838023 AppendixMin. level for accept of ultrasonic echoEnter the access code (see page 58) and press 'Shift' +

Página 64

67SW 838023GB Shuttle Manual 100316 AppendixUse the arrow keys to select a new value:Confirm the new setting:The actual setting is shown immediately:

Página 65

68GB Shuttle Manual 100316SW 838023 AppendixChanging the access codeEnter the access code (see page 58) and press 'Shift' + 'D'Us

Página 66

69SW 838023GB Shuttle Manual 100316 AppendixF New sensor / changing sensorShuttle® will be shipped and delivered from about July 1, 2007 with 1 of

Página 67

7SW 838023GB Shuttle Manual 100316 MountingMountingGeneralShuttle® measures the level by sending an ultrasonic signal against the surface and measuri

Página 68

70GB Shuttle Manual 100316SW 838023 Ultrasonic Level Transmitter and SensorDK: +45 45 56 06 56NO: +47 69 20 60 70SE: +46 53 31 77 50NL: +31 251 6

Página 69

8GB Shuttle Manual 100316SW 838023 MountingUltrasonic sensorTwo things are extremely important when mounting the ultrasonic transmitter: (See also ap

Página 70

9SW 838023GB Shuttle Manual 100316 MountingElectrical mountingLevel transmitterThe Shuttle® must not be connected to the power supply before the ultr

Comentários a estes Manuais

Sem comentários